PROJECT 619033
Not run
Sunrun Finance
Ready to validate.
Run all photo checks against finance requirements before submitting.
40
Checks
5
Categories
~45s
Est. time
Commissioning
8
Electrical
14
Rooftop Installation
16
Job Check-In
3
Site & Safety
8
PROJECT 619033
0:00
Scanning
Analyzing photos.
Reviewing each photo against Sunrun Finance requirements.
0 / 40
Checks
Commissioning
Waiting
Electrical
Waiting
Rooftop Installation
Waiting
Job Check-In
Waiting
Site & Safety
Waiting
PROJECT 619033
Run · 10:42 AM
Sunrun Finance
Not ready to submit.
7 checks failed across 3 categories. Fix the items below before re-running.
7
Failed
2
Warning
31
Passed
COMM
Company / Partners field is wrong.
Partners shows "Freedom Forever" only. Must read "Sunrun Inc (USA)" — both entities required. Re-take after editing in Settings → Partners.
COMM
Wrong screen captured for Customer Reg.
You photographed the "Registration Complete" success screen. Re-take on the address form screen so Street, City, State and Zip are visible.
COMM
Backup Test screenshots missing.
Whole Home Backup requires 2 screenshots from the backup transfer test. 0 found. Run the test and capture both screens.
COMM
On Grid screenshots missing.
WHB systems require 2 "On Grid" screenshots, captured while system is live on grid. None found.
COMM
Meter Test timestamp unclear.
Photo found, but the timestamp may be cropped. Re-take so the full screen — including timestamp — is captured.
ELEC
Battery photo missing — cover on.
Only wiring-compartment photos found (cover removed). Take a separate full-unit photo with the cover installed and unit mounted.
ELEC
Utility meter photo missing.
No dedicated meter photo found. Photograph the utility meter socket — separate from other BOS equipment photos.
ELEC
Gateway DIN number may be cropped.
Both Serial Number and DIN number must be clearly readable. Verify or re-take.
ROOF
Array 2 module labels missing.
Array 1 has 3 label photos. Array 2 is empty. Each array needs a label photo with readable serial barcode.
31 passedof 40
Tesla Self-Test
Grid Profile · IEEE 1547-2023
Network · WiFi / Internet / Tesla
Battery Serial Number
Inverter Serial Number
BOS Step-Back · Covers On
TPW3 Label · Barcode + Model
Array Photos · Both arrays
Module Count matches design (18)
Front of House · Address visible
Vehicle Safety · Cones deployed
Electrical Safety PPE
Roof Safety · All crew members
PROJECT 619033
Run · 10:42 AM
Sunrun Finance
Ready to submit.
All 40 checks passed. This project meets every Sunrun Finance requirement.
40 / 40
Passed
0
Failed
Commissioning
8 / 8
Electrical
14 / 14
Rooftop Installation
16 / 16
Job Check-In
3 / 3
Site & Safety
8 / 8